How to ensure drainage systems continue to work effectively

Key points when cleaning systems
To ensure a green space is fit for its intended use and remains in good condition over time, a suitable drainage system is sometimes essential. Such systems are used on farmland as well as golf courses and sports grounds. At Delvano, they know that simply having a system in place is no guarantee of long-term performance. The range offered by the agricultural machinery manufacturer and distributor includes several drain cleaners made by Dutch manufacturer SS Engineering.
Words Elise Noyez | Photography SS Engineering
A poorly functioning drainage system leads to an unsuitable groundwater level, leaving the soil too wet, keeping soil temperatures too low and restricting plant growth. On golf courses and sports pitches, it can also make the ground unplayable. Proper maintenance of drainage pipes is therefore essential, although there are a few points to bear in mind.
Not all soils are the same
In principle, drain cleaners are suitable for all drainage systems. However, the frequency with which drains need flushing depends largely on the soil type. As a rule of thumb, drainage systems in sandy soil should be flushed every two to three years, while in heavy clay soil, flushing every four to five years is sufficient.

The Professional drain cleaner is an all-rounder, suitable for all types of drainage system with lengths of between 300 and 700 metres.
Drainage systems in iron-rich soils are best cleaned every year. Given the current drought conditions, iron ochre will form quickly in the soil and block the perforations in the drainage pipes. SS Engineering has developed a special nozzle for this purpose.
It’s all about timing
To flush efficiently without damaging the soil, flushing should only be carried out when the soil is wet. This prevents the flushing water from seeping into the soil through the system.
Care must also be taken not to send too much water through the drain, so that only the pipe itself, and not the surrounding soil, is flushed out. For the SS Engineering Professional drain cleaner and standard drains measuring 6.5 centimetres in diameter, a speed of 30 metres per minute is generally considered the minimum. Fortunately, the integrated metre counter makes this easy to check and set.